1dl code on goodman furnace - To check for these signs of a dirty or defective furnace sensor, follow these steps: Switch off the furnace. Close the gas supply valve. Open the furnace and locate the flame sensor. Assess the flame sensor for soot and corroding or cracked/damaged sensor porcelain insulation.

 
Turn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.. How much is gas at bj

The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up.Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.I have problem with bryant furnace mod#379CAV036070AGJA just to call for heat the board display code #12 (HK42FZ011) so we wait some time and after that the board run a perfect cycle,run inducer,fire …CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43.Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician code (if there is no fault or protection code it will be display “nn”) Normal display Display “--” Operating mode 3—Heating; 4—Forced cooling) Operating fan speed grade (0—Power off) The total capacity requirements of the interior unit The capacity requirements of the revised external unit T3 piping temperature T4 environmert ... CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43.We recently had a new Goodman furnace installed. We have an old programmable Honeywell thermostat. The problem I'm having now is that the thermostat reads 68 (is set to 75) and the furnace isn't comin … read moreTurn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.Goodman error code 7P1 is IDLTo receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ...1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor.CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long.Apr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. Hi just hooked up my Goodman furnace and as soon as I put the power on the 3:00 a.m. fuse blue. AnyHi just hooked up my Goodman furnace and as soon as I put the power on the 3:amp. fuse blew. Any sugg … read moregoodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read moreCode 1-3: Indicates that a limit flame switch problem that normally auto-resets after 3 hours. Code 1-4: Represents an ignition problem. However, the furnace will auto-reset after some hours. Code 2-1: This is a sign of gas heating lockout. You need to check if the gas valve wiring is correct.Remove the access panel on your Trane furnace. Locate the dirty air filter. It should be near the return air duct or the blower chamber’s entrance. Remove the old air filter and slide in a new one. Ensure that signifiers indicate that the new filter is installed correctly. Replace the panel or door to your Trane furnace.code (if there is no fault or protection code it will be display “nn”) Normal display Display “--” Operating mode 3—Heating; 4—Forced cooling) Operating fan speed grade (0—Power off) The total capacity requirements of the interior unit The capacity requirements of the revised external unit T3 piping temperature T4 environmert ... Mar 26, 2022 · I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace. 1dl code has appeared on our Goodman ac, Yes to both. Since last night, reset everything, ... I hav e GMV95 Goodman Furnace and air about 6 months old. Air has worked ...Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control.Apr 12, 2023 · No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes. https://www.alwaysopen.caGoodman Furnace Fault CodesTurn off the furnace or the breaker box. Check the filter to make sure it’s clean, and replace it if necessary. Inspect the furnace and vents for dirt and debris, and vacuum them if necessary. Turn the furnace back on. Check that the thermostat is set to Heat and set for higher than room temperature.Done That · #12 · Jul 25, 2016. You have a 2-stage furnace and a 2-stage AC only outdoor unit. So the only terminals that need to be wired for correct operation are R,C,G,W1,W2,Y1,Y2. If you posted pics of the wiring at the thermostat, furnace board, and outdoor board we could probably straighten this out.The duration of warranty coverage in Texas and Florida differs in some cases. ** For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the ... The CoolCloud HVAC application allows contractors to connect and communicate wirelessly via Bluetooth with Goodman and Amana premium air handler and furnace control boards. This provides a more efficient means for servicing and maintaining equipment, making configuration adjustments, gaining equipment status, performing diagnostics, viewing ...CODE: 2 Flashes. RESULT: The furnace is likely blowing cold air because it's dropping the flame. CODE: 3 Flashes. RESULT: Indicates a problem with the pressure switch. CODE: 4 Flashes. RESULT: Indicates a problem with the limit switch. CODE: 6 Flashes. RESULT: Indicates a problem with the polarity or grounding. I have a Amana AM9C960603ANAA. I'm getting 2 codes on the LCD display. First is 1dl and the second one is EE5. What do - Answered by a verified HVAC TechnicianAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...My brand new 2 ton Goodman is tripping the cb when outside 8/7/2023. I have an issue with my Goodman air conditioner, I do not 8/6/2023. I have a Goodman central air unit washed the condenser clean 8/6/2023. Ok. Opening a new thread I have got a Goodman heat pump unit 8/3/2023. I'm working on a Goodman 5 ton and the high pressure lines 8/1/2023.specified on the furnace rating plate and OPERATIONAL CHECKS section of these instructions. When furnace duct(s) supply air outside the space contain-ing the furnace, a return air duct must terminate in the same space as the supply duct and be sealed to the furnace casing. A gas-fired furnace for installation in a residential garageLast Udated: August 23, 2023. The Goodman 1DL error code is a common problem in Goodman furnaces. It indicates a problem with the low-voltage transformer, which provides power to the furnace’s control board and other components.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.The CoolCloud HVAC application allows contractors to connect and communicate wirelessly via Bluetooth with Goodman and Amana premium air handler and furnace control boards. This provides a more efficient means for servicing and maintaining equipment, making configuration adjustments, gaining equipment status, performing diagnostics, viewing ... About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...No Still going up this codes. F01 EE0. HVAC Technician: airheatman. If it lights and goes out try cleaning the flame sensor and see if that helps. Code says the board is not receiving signal that we are getting flame. Ask Your Own HVAC Question. HVAC Technician: airheatman.Open the gas valve fully in a counterclockwise motion to make sure the gas supply is turned on. Increase the temperature on the thermostat, and turn the mode to "Heat" after making sure the vents are all clear of blockages. Disconnect the power to reset the furnace, and contact Trane if necessary.As an armature, I have some experience troubleshooting furnace problems. I have a 1.5 ton Goodman furnace that cools and heats. The circuit bd. Is B25578-00A. The unit is 25 years old and has been wor … read moreThe controller will indicate a fault condition by flashing the fault LED. The flashing pattern will be ¼ second on and ¼ second off for each count, if multiple faults are present it will dwell 2 seconds between each fault code, then dwell 5 seconds and repeat until the fault(s) are cleared. Listed below are the fault codes. 1 flash – Not UsedFeb 10, 2023 · Besides Goodman fault codes, there are the messages which can also appear, status and data related to these codes. This information can give you the idea about any necessary further actions – for example, 3 flashes mean that Goodman pressure switch stuck open, and 2 flashes mean the same part stuck closed. Jan 25, 2020 · 1. the thermostat demand signal is intermittent. 2. Time delay relay or control board faulty. 3. If high pressure switch is present, go to Flash Code 2 information. 4. If a low pressure switch is present, go to Flash Code 1 information. Status LED: Yellow “ALERT” Flash Code 4. Status LED Description: off rotor. I am always available if you want to use your “Request Call Option “ And if you don’t get another message right after this greeting it’s because I’m more then likely I’m in the process of writing another message to you. that number is ***** the air conditioning coil that is on top of the furnace.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3.Turn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC noticeSelect the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Mar 23, 2017 · Troubleshooting GMEC96 Fault Status Codes •Fault Code Example 1: Status light displays “4 Red flashes.” •Refer to the “troubleshooting” chart on page 44 of the GMEC96 service manual. •Also, find your “fault symptoms and description” in the troubleshooting chart on pages 42-43. HVAC Technician: RobHVAC. No problem. Or you can just touch the two terminal screws together with the wire until the unit turns on. Ask Your Own HVAC Question. FO4 IRC it turned on. HVAC Technician: RobHVAC. OK so that means that the issue is the thermostat not the unit.No signal from the thermostat. Turn off the unit’s power and check connections. Single LIGHT flash. Furnace lockout due to an excessive number of ignition retries. Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. 2 LIGHT flashes.RESULT: No signal from thermostat. FIX: Turn off power and check connections. CODE: One led that flashes. RESULT: Furnace lockout after three attempts to fire. FIX: Locate and correct gas interruption. Reset by lowering it for 20 seconds and then raise it back, furnace will reset itself after one hour. goodman furnace tech support. Its a 2018 model goodman and i get 3 led flashes, the igniter glows real bright and then dims. We tried to jump the pressure switch but the furnace did the same thing it … read moreRemove the access panel on your Trane furnace. Locate the dirty air filter. It should be near the return air duct or the blower chamber’s entrance. Remove the old air filter and slide in a new one. Ensure that signifiers indicate that the new filter is installed correctly. Replace the panel or door to your Trane furnace.Hi just hooked up my Goodman furnace and as soon as I put the power on the 3:00 a.m. fuse blue. AnyHi just hooked up my Goodman furnace and as soon as I put the power on the 3:amp. fuse blew. Any sugg … read moreHVAC Technician: RobHVAC. No problem. Or you can just touch the two terminal screws together with the wire until the unit turns on. Ask Your Own HVAC Question. FO4 IRC it turned on. HVAC Technician: RobHVAC. OK so that means that the issue is the thermostat not the unit.Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.Feb 4, 2017 · Hi just hooked up my Goodman furnace and as soon as I put the power on the 3:00 a.m. fuse blue. AnyHi just hooked up my Goodman furnace and as soon as I put the power on the 3:amp. fuse blew. Any sugg … read more Mar 1, 2022 · Code 1 – Furnace ignition failure. The control board has detected that the furnace failed to ignite. The control board has detected that the furnace failed to ignite. This could be due to low voltage, high resistance, or dirty terminals on the furnace primary control. Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...Welcome to TWINTECH Heating & Cooling Keeping families comfortable for over 30 years. Check out our seasonal promotions. TWINTECH is a full-service HVAC care and maintenance provider located in Durham, Ontario.Feb 25, 2023 · Goodman error code 7P1 is IDL View and Download Goodman AVPTC42D14 series installation & operating instructions manual online. AVPTC**14 series. AVPTC42D14 series air handlers pdf manual download. Also for: Avptc48d14 series, Avptc30c14 series, Avptc36c14 series, Avptc24b14 series, Avptc48c14 series, Avptc60d14...To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty, online registration must be completed ...goodman furnace codes The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart. Goodman is one of the biggest names in home heating and energy efficient home comfort.A quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre...October 28, 2021 Goodman furnaces have a display panel with a built-in trouble-code that uses LED lights to show the homeowner that there is a malfunction of some sort. What do these error codes mean and is there anything that you can do to fix these problems? Here is everything that you need to know. Goodman Furnace Error CodesGMES80-U. Goodman furnace features: Multi-speed motor, ultra-low NOx, fault code LED output, quiet draft inducer. Pros and cons: With an 80 percent AFUE rating, this is one of Goodman’s least efficient furnaces. This is a single-stage model, which means it is a less energy efficient but more affordable option.I need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t...goodman furnace codes The flashing LEDs on your furnace will correspond to a specific fault code that is shown here on their diagnostic chart. Goodman is one of the biggest names in home heating and energy efficient home comfort. The duration of warranty coverage in Texas and Florida differs in some cases. ** For installation in California’s South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule 1111 14 ng/J NOx emission limit, and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the ...May 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. Turn off the furnace power and repair a short or replace the pressure switch. 4. Read three LED flashes to mean your furnace has an open pressure switch circuit or it has an induced draft blower operating. Check the pressure switch hose of your furnace for blocks or an improper connection.Goodman furnaces are among the most recognized and respected forced-air heating systems. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Many components ...View the user manual below for more details. Want a copy for yourself? Download or print a free copy of the user manual below. GAS FURNACE (INSTALLOPERATING) (viewing) Download PDF. Owner’s Manual. Top Parts. Models. Showing 10 of 12 parts. Show.67. Ambient Temperature Sensor Fault (Out of Range – Open or Shorted) ERR 67. 6 Flash. Coil Temperature Sensor Fault (Out of Range – Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle power to reset) ERR 79.Instructions: 1. Select the brand from the drop down menu 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button. © 2011 Goodman Manufacturing Company, LP. All rights reserved.Jul 1, 2022 · Brand new and it is a goodman ace furnace dont have the model number with me. Tried the reset - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website. The furnace filter is generally on the return duct right before the furnace. A dirty filter causes blockage of airflow. A dirty filter causes blockage of airflow. This results in a furnace overheating and shuts off too quickly before your house gets heated up.Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC TechnicianTroubleshooting b1 fault code on a Goodman communicating air handler HVAC Technician: airheatman , HVAC Technician replied 7 years ago Take a look at this manual on troubleshooting these motors and let me know if you want to get the tester and determine if issue is in motor or boardMay 11, 2019 · STATUS: Discharge Air Too Hot. SUGGESTED ACTION: Clean Filter or Remove Air Blockage. CODE: LC. STATUS: Outdoor Coil Thermistor temperature high. SUGGESTED ACTION: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning. CODE: C2. STATUS: Indoor Air Recirculation. Large delta between thermostat and return. GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P. GOODMAN MES9 & CES9 FURNACE INSTALLATION INSTRUCTIONS [PDF] (2019) GOODMAN FURNACE HIGH TEMPERATURE PLASTIC VENT HTPV SAFETY RECALL [Web article] US CPSC noticeA quick look at goodman trouble codes on a goodman furnace. Some simple hints on what those codes can indicate what the problem could be. Amazon link to Gre...

Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician . Medm

1dl code on goodman furnace

My goodman furnace's diagnostic display reads 88. I was away for work and my girlfriend said it was reading e5 so I got her to cut power and change 3 amp fuse. Now it says 88 and im stumped. Furnace d … read moreWe experienced a power outage and when the power came back on our furnace blows cold air but will not ignite. I believe it is a 3 yr. old Goodman model no. CAPF486OC6AA. I noticed a blinking code of 4 … read more The AVPTC61D14 air handler is rated for an output of 5 tons. In many cases, this tonnage will be larger than the condenser it is paired with, which increases the overall efficiency of the unit. Please note that this air handler needs a condenser to heat or cool. For straight heating or when backup heat is necessary in a heat pump application ... I need your assistance with the Amana and Goodman furnace E5 error code.After the LED segment 2 shows you E and the segment one shows the 5, this is one of t...Select the brand from the drop down menu. 2. Next select the model number from Model drop down box. 3. Move through the remaining menus. 4. Once all menus have been satisfied push the SUBMIT button. 5. To reset the search for a new search click the SEARCH button.CODE: b9. RESULT: Indoor blower motor problem./Blocked filters./Restrictive/ undersized ductwork./Indoor-outdoor unit miss match. CODE: d0. RESULT: Air conditioner/heat pump is wired as part of a communicating system and integrated control module does not contain any shared data. CODE: d1.Jan 12, 2023 · Get professional furnace and air conditioning installation, maintenance, and 24-hour repair services with SNAP Heating & Air Conditioning. Our licensed and experienced technicians are available around the clock to provide prompt and reliable service to keep your home comfortable all year long. Sep 29, 2022 · If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3. A 1dl code on the Goodman furnace uses a digital thermostat to regulate and control the furnace, saving time and energy. A digital thermostat is an electronic device that regulates the heating of buildings or spaces to regulate the conditions inside.If the furnace is running, turn the thermostat off and allow the furnace to cool and the blower to stop operating. Initiate a call for heat from the thermostat and monitor the ignition sequence. 1. The inducer motor should start with no difficulty. 2. The pressure switch should close within a couple seconds of the inducer starting. 3.Dec 23, 2022 · Goodman manufacturing. it is displaying code 1dl and the green light is flashing two long, five short. anything I can - Answered by a verified HVAC Technician FIX: Adjust the gas pressure according to the information available to you. CODE: Eight LED flashes. PROBLEM: This means your furnace has an igniter circuit problem due to a defective igniter or an improperly connected igniter. FIX: Replace the igniter or check the ground wiring for defects. CODE: Nine LED flashes..